INPUT DATA

Number of MPP trackers

2,0

Max. input current (Idc max)

18 / 18 A

Max. short circuit current, module array

27 / 27 A

DC input voltage range (Udc min - Udc max)

80 - 1000 V

Feed-in start voltage (Udc start)

80,0 V

Nominal input voltage (Udc,r)

710,0 V

MPP voltage range (Umpp min - Umpp max)

240 - 800 V
Usable MPP voltage range80 - 800 V
Number of DC connections2 + 2

Max. PV generator power (Pdc max) 

7,5 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)

4600,0 W

Max. output power (Pac max)

5000,0 VA

AC output current (Iac nom)

21,7 A

Grid connection (Uac,r)

1~ NPE 220/230 V

AC voltage range (Umin - Umax)

180 - 270 V

Frequency (fr)

50 / 60 Hz

Frequency range (fmin - fmax)

45 - 65 Hz

Total harmonic distortion

< 5 %

Power factor (cos φac,r)

0,85 - 1 ind./cap.

GENERAL DATA

Height645,0 mm
Width431,0 mm
Depth204,0 mm
Weight21,5 kg
Degree of protectionIP 65
Protection class1,0

Overvoltage category (DC / AC) 1)

2 / 3
Night-time consumption< 1 W
Inverter designTransformerless
CoolingRegulated air cooling
InstallationIndoors and outdoors
Ambient temperature range-40°C - +55°C
Permitted humidity0 - 100 %

Max. altitude 2)

4.000 m
DC connection technology4x DC+ and 4x DC- screw terminals 2.5 - 16 mm²
AC connection technology3-pin AC screw terminals 2.5 - 16 mm²
Certificates and compliance with standardsDIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,<br /> AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105

EFFICIENCY

Max. efficiency (PV - grid)98,1 %
European efficiency (ηEU)97,1 %

η at 5% Pac,r 3)

80,8 / 82,5 / 82,5 %

η at 10% Pac,r 3)

89,6 / 94,8 / 93,1 %

η at 20% Pac,r 3)

93,4 / 97,2 / 96,2 %

η at 25% Pac,r 3)

94,1 / 97,3 / 96,8 %

η at 30% Pac,r 3)

94,7 / 97,4 / 97,0 %

η at 50% Pac,r 3)

95,8 / 97,9 / 97,7 %

η at 75% Pac,r 3)

96,1 / 98,0 / 97,9 %

η at 100% Pac,r 3)

96,2 / 97,9 / 97,9 %
MPP adaptation efficiency> 99,9 %

PROTECTION DEVICES

DC insulation measurementYes
Overload behaviourOperating point shift, power limitation
DC disconnectorYes
Reverse polarity protectionYes

INTERFACES

WLAN / Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputsInterface to ripple control receiver

USB (type A socket) 4)

Data logging, inverter update via USB flash drive

2x RS422 (RJ45 socket) 4)

Fronius Solar Net

Signalling output 4)

Energy management (floating relay output)
Datalogger and web serverIntegrated

External input 4)

S0 meter connection / Evaluation of overvoltage protection
RS485Modbus RTU SunSpec or meter connection

 